Universal EV Chargers

Universal EV Chargers

Tesla EV Car Charging System

Image

Gen 3 Wall Connector - 7.3m

Wall Connector is the most convenient charging solution for houses, apartments, hospitality properties and workplaces.

With up to 71 km of range added per hour of charging, multiple power settings, 7.3m length and a versatile indoor/outdoor design, Wall Connector provides unparalleled convenience.

Wall Connectors can power-share to maximize existing electrical capacity, automatically distributing power to charge multiple cars simultaneously.

Note: Gen 3 Wall Connector is compatible with both Single and Three Phase power. Please follow the instruction manual to set up according to the power supply at the place of installation.

Universal EV Charger

Image

EV charger Selection Guide

1-phase from 1.3kW to 7.4kW or 3-phase from 4.1kW to 22kW

BCP Series EV chargers have an lP65 patented design-case for outdoor and indoor use.

The type 2 (IEC 62196-2) charging connector makes highly flexible and compatible with all electric vehicles.

Plug and start to charge automatic. (RFID card for option)

The EV charger output power can be adjusted from 6A all the way up to 32A.

Charging protocol OCPP1.6J is optional.

Image

Three phase EV charger model

three phase ev charger model

Single phase model (PEN function is only for UKCA certificate)

three phase ev charger model

Functions Explain

Image

Dynamic Load Balancing

DLB (Dynamic Load Balancing) is available in the BCP series AC EV Charger for home use, when the EV charger is working with other household appliances at the same time, the DLB box can maintain the dynamic balance of the total household current and ensure the safety of electricity to avoid home over load.

Set the Max current value of the main line on the DLB box. The charger will read this current value and automatically adjust the charging current (6A-32A) according to the idle load quota, so that the total household current will not be overloaded due to charging. This function can effectively use the power supply without providing additional power for the charging or home line update.

Image

RFID(Radio Frequency identification Card)

RFID card reader enabled to start up charging function while approaching the swipe area.

Image

PEN Fault Detection

Image

For TN-C-S systems without grounding at the user's end (as shown above), when the PEN line to the household is cut off due to a line fault and the rear end of the PEN line is in suspension without repeated grounding, and the distribution box RCD is not working properly at this time, the voltage of the protective ground PE is equal to the voltage of the fire line L. If not equipped with this protection,the shell of the EV in charging will be charged with a voltage equal to the fire line L voltage. If there are no other appliances except the EV charger, the leakage current will exceed 30mA and the person will not be able to disengage himself, which is a safety hazard; if there are even other appliances, the leakage current can easily exceed100mA, which is very fatal.

If the user uses a EV charger equipped with PEN protection as shown above (model with -E suffix), its internal design has a contactor to cut off the ground, once the PEN line is cut off, the contactor KM1 and KM2 immediately and automatically disconnected, there is only a weak leakage current between CP and PE to L line, its current value is less than 1mA, which is the smallest perceived leakage current of the human body, people can disengage themselves, no safety risks.

Image

Smart APP

  • The EV charger can be controlled by smart APP via WIFI or bluetooth connection:
  • One to one binding EV charger by reset the password, prevent the EV charger being stolen
  • View charging data and status;
  • Set up various charging configurations,charging current,DLB mode,etc. Scheduled charging
  • Firmware updates

SPECIFICATIONS

Electrical

Charging capacity
Charge mode
Output power
Connector options
Fixed cable length
Cable Entry
Charge mode
Mode 3 (IEC 61851-1)
Selectable 1-phase or 3-phase, 230-400V 6A -32A, 50-60Hz
Fixed cable type 2 plug or type 2 Socket
6m (18 ft)
Rear or bottom

Protection and certification

Build-in RCD
With cable
Socket
Housing fire ratings
Operating temperature
Charging capacity
Compliance
TYPE A + DC6mA leakage sensor built-in
IP65,IK07
IP55,IK07
V0
-25~+55°C
CE, UKCA, SAA
IEC61851-1,IEC61851-21-2,IEC61000-4
CE EMC EU/2014.CE Low Voltage EU/2014/35

Connectivity

Authorisation
Status indication
WLAN communication
Charging protocol
Auto-start standard / RFID card option
LED ring
Wi-Fi / Bluetooth 4.2 option
OCPP1.6J optional

Mechanical

Housing
Dimension
Mounting
Polycarbonate
W169 x H380 x D151 mm
Wall or Pole

Model Selection

baxter-electrical-logo-no-background.png

Specialists in the maintenance and repairs of solar systems.

Image
Image
Image

Frequently Asked Questions

How often should I have my solar system serviced?
Due to the extreme weather conditions in Australia, most manufactures recommend a licensed electrician services your system once every 12 months, in some cases this is required for warranty upkeep. See more about solar servicing.
Is my solar system working as efficiently as it should?
I have a fault on my solar inverter, what should I do?