Check 'Solar Supply Main Switch' is ON; If fault code remains you will require on-site diagnosis by a trained Swift Solar Repairs technician. Contact us immediately to resolve this issue.
AC grid outside the permissible safe limit! This identifies an issue with the grid supply to your property which can be dangerous, your inverter has responded by shutting down. Contact us immediately to resolve this issue.
Inverter Over Temperature: This fault indicates the inverter internal temperature is exceeding safe limits, this is often shown on hot days unless the inverter is incorrectly reading a high temperature. Acknowledge fault code, shutdown inverter, restart after 2 mins; If fault code remains you will require on-site diagnosis by a trained Swift Solar Repairs technician. Contact us immediately to resolve this issue.
Internal CPU Failure: Communication between the master and slave CPU has failed
Isolation fault/Ground fault: this indicates voltage has been detected by the earthing system
PV Undervoltage: This fault indicates the array voltage is below inverter MPPT range, this is often shown in twilight hours when the sun is low in the sky, unless the inverter is incorrectly reading a low input voltage and needs to be repaired.
PV Overvoltage: This fault indicates the array voltage is exceeding safe inverter limits, this is often shown on cold mornings unless the inverter is incorrectly reading a high input voltage and needs to be repaired.
PV Overcurrent!: This fault indicates the array current is exceeding safe inverter limits, this is often shown if the PV system is incorrectly designed (incorrect inverter used) and requires the inverter to be changed.
Extreme risk identified! Shutdown inverter immediately, you will require on-site diagnosis by a trained Swift Solar Repairs technician. Contact us immediately to resolve this issue.
Technician Required! Your solar system requires on-site diagnosis from a trained Swift Solar Repairs technician. Contact us immediately to resolve this issue.
Acknowledge fault code, shutdown inverter, restart after 2 mins; If fault code remains you will require on-site diagnosis by a trained Swift Solar Repairs technician. Contact us immediately to resolve this issue.
Inverter Commissioning Error: This fault indicates a failed commissioning process or CPU internal error. Acknowledge fault code, shutdown inverter, restart after 2 mins; If fault code remains you will require on-site diagnosis by a trained Swift Solar Repairs technician. Contact us immediately to resolve this issue.
Technician Required! Your solar inverter output is derating, this requires on-site diagnosis from a trained Swift Solar Repairs technician. Contact us immediately to resolve this issue.
Replacement inverter required! Your solar system requires a 3 phase inverter capable of high DC input current - Click through to the Inverter Shop to see your system design-compatible options. To avoid compatibility issues with your system, a 3 phase inverter is recommended.
Replacement inverter required! Your solar system requires an inverter capable of high DC input current - Click through to the Inverter Shop to see your system design-compatible options. To avoid compatibility issues with your system, a high DC input current inverter is recommended.
Replacement inverter required! Your solar system requires a Transformer-based inverter - Click through to the Inverter Shop to see your options. To avoid compatibility issues with your system, a Transformer-based inverter is recommended.
Replacement inverter required! Your solar system requires a topology upgrade to allow a replacement inverter - Click through to the Inverter Shop to see your system design-compatible options. To avoid compatibility issues with your system, a topology upgrade is recommended.
Any additional info about the solar system